All FLIR infrared cameras are precision instruments that are factory calibrated to record the best possible thermal images and non-contact temperature measurements. Moreover, electronic stabilization circuitry helps maintain this calibration as temperature varies. Nevertheless, electronic component aging over time can cause calibration shift. This means that your FLIR camera should be checked periodically for measurement accuracy, and recalibrated as needed.

How IR Camera Calibration Service Process goes?
The calibration of each FLIR camera model is unique. Therefore, Our Company is uniquely qualified to keep your camera in peak operating condition for optimum reliability and accuracy in data collection. This division is certified according to ISO 9001:2008 (Nov. 2010).

How often do I need to calibrate my IR camera?
We recommend getting your thermal imaging camera calibrated annually to ensure that your camera is still testing within parameters set by the manufacturer.

REQUST FOR A QUOTATIONREQUEST FOR MORE INFORMATION

 

Features and Benefits:
Why Calibration is so important?
FLIR cameras are designed and factory calibrated for accurate temperature measurements and thermal imaging. When maintained with FLIR’s periodically calibration services, they will be highly reliable in spotting thermal anomalies and other temperature phenomena. Without proper maintenance and calibration, accurate measurements cannot be assured.
– Cameras and detectors are aging.
– Optic system including detector window can overtime be polluted by dust / dirt – can effect reading.
– Measurement errors in the field cannot be detected easily.
– Only FLIR Service Centers are able to recalibrate FLIR Thermography cameras.
– Accordingly calibration will reset camera close to the set of temperatures making measurement faults less likely within next time period for all temperature Ranges up to 1500C degree and all lenses.
– FLIR Service Calibration is annually calibrated and traceable to world-wide standard
– An Accuracy protocol to be performed
– after every Calibration to make sure is done correctly.
– FLIR Service have access to:
1. Camera full history.
2. Latest firmware and configuration files.
3. Production server files to be able to recover the camera when it was hipped.
4. Production capability / equipment.
– FLIR Service Center offer General maintenance and calibration including 14 point check.
– Image improvements, Kill bad pixels, perform gain mapping to improve image quality.
– During General maintenance a full operational check will be done includes performing NUC, diagnose tests.
– During General maintenance, fusion, MSX calibration, laser alignment, minor repairs.
– Other Calibration Labs are able to do an accuracy check for FLIR camera manually only by measuring couple of heat sources and comparing the results so it is NOT Calibration.
– Other Calibration labs do NOT have an access for FLIR camera service web so they will NOT be able to recalibrate the camera and correct the camera error.
– All 14 Points Check which FLIR offer like (Fusion, MSX Calibration, laser alignment, Gain Mapping, pixel killing, Diagnostics Tests ……) can NOT be done by other service labs.
– Other labs are NOT able to perform any repair in case it is needed.

“At the end Thermography cameras are a test and measurement tools and should be calibrated according to quality audits and reports.”