Home > Products > Automation > FLIR A310 pt

FLIR A310 pt

  • 0
  • Sunday March 6th, 2016
a310pt1

Advanced RFM System Visible CCTV + Thermal Imaging


a310pt2

Visual Image vs. Thermal Image

 

 

 

 

 

 

 

 

REQUEST FOR QUOTATIONREQUEST FOR MORE INFORMATION

 

FLIR A310 pt (pan-tilt) monitoring systems are designed to withstand the elements to remotely collect valuable data. “Smart” thermal imagers and software can alert operators to security breaches and impending problems indicative of excess heat 24/7/365 while monitoring: electrical substations, hazardous material piles, warehouses, and critical vessels.

• FLIR’s PT-Series of high-performance, multi-sensor pan/tilt cameras bring thermal and visible-light imaging together in a system that gives you video and control over both IP and analog networks.
• The PT-Series’ precision pan/tilt mechanism gives you accurate pointing control while providing fully programmable scan patterns, radar slew-to-cue, and slew-to-alarm functions
• RFM can easily identify if Pilot Flame is on or off.
• Risks of high consequences due to unburned released gas is reduced.

FLIR A310 pt – Pan/tilt
Operating temperature range –25°C to +50°C
Encapsulation IP 66 (IEC 60529)
Bump 5 g, 11 ms, (IEC 60068-2-27)
Weight 17.9 kg
Camera size (L × W × H) 460 x 467 x 326 mm
Tripod mounting N/A
Base mounting TBA
Automatic heaters Clears ice from window
Azimuth range Az velocity 360º continuous, 0.1 to 60º/sec max.
Elevation range El velocity +/- 45º, 0.1 to 30º/sec. max.
Programmable presets 128
Ethernet, video streaming Two independent channels for each camera -MPEG-4, H.264 or M-JPEG
External power operation 24 VAC (21-30 VAC) 24 VDC (21-30 VDC)
Consumption 24 VAC: 215 VA max w/heater
24 VDC: 195 W max w/heater

 

Imaging and optical data
Field of view (FOV) / Minimum focus distance 25° × 18.8° / 0.4 m
Lens identification Automatic
Thermal sensitivity/NETD < 0.05°C at +30°C / 50 mK
Focus Automatic or manual (built in motor)
F-number 1.3
Image frequency 30 Hz
Zoom 1–8× continuous, digital, interpolating zooming on images
Detector data
IR resolution 320 × 240 pixels
Detector pitch 25 μm
Detector time constant Typical 12 ms
Focal Plane Array (FPA) / Spectral range Uncooled microbolometer / 7.5–13 μm
Measurement
Object temperature range –20 to +120°C
0 to +350°C
Accuracy ±2°C or ±2% of reading
Set-up
Color palettes Color palettes (BW, BW inv, Iron, Rain)
Set-up commands Date/time, Temperature °C
Storage of images
Image storage type Built-in memory for image storage
File formats Standard JPEG, 16-bit measurement data included
Composite video
Video Composite video output, PAL and NTSC compatible
Video, standard CVBS (ITU-R-BT.470 PAL/SMPTE 170M NTSC)
Digital input/output
Digital input 2 opto-isolated, 10–30 VDC
Digital output, purpose As function of ALARM, Output to ext. device
(programmatically set)
Digital output 2 opto-isolated, 10–30 VDC, max 100 mA
Digital I/O, isolation voltage 500 VRMS
Digital I/O, supply voltage 12/24 VDC, max 200 mA
Digital I/O, connector type 6-pole jackable screw terminal
Digital input, purpose Image tag (start/stop/general), Input ext. device (programmatically read)
Ethernet
Ethernet, standard IEEE 802.3
Ethernet, connector type RJ-45
Ethernet, type 100 Mbps
Ethernet, communication TCP/IP socket-based FLIR proprietary
Ethernet, power Power over Ethernet, PoE IEEE 802.3af class 0
Environmental data
Storage temperature range –40°C to +70°C
Humidity (operating and storage) IEC 60068-2-30/24 h 95% relative humidity
+25°C to +40°C
EMC • EN 61000-6-2:2001 (Immunity)
• EN 61000-6-3:2001 (Emission)
• FCC 47 CFR Part 15 Class B (Emission)
Vibration 2 g (IEC 60068-2-6)
Physical data
Housing material Aluminium
Scope of delivery
Hard transport case or cardboard box, thermal imaging camera with lens, utility CD-ROM, calibration certificate, Ethernet™ cable, mains cable, power cable (pig-tailed), power supply, user documentation CD-ROM, printed documentation, 6-pole screw terminal (mounted on camera)

Inquire more about FLIR A310 pt.

Sending Message

Related Categories

Automation